Summary Table

Item

Description

Function

Continuously lifts and removes tramp ferrous metal from a conveyor carrying hot bulk material

Standard circuit limit

NdFeB (N-grade): continuous material duty up to ~80°C

Hot-duty circuit options

Ferrite (up to 250–300°C), NdFeB H/SH/UH/EH (120–200°C), SmCo (250–350°C), Class H electromagnet (up to ~180°C coil zone, oil-cooled higher)

Cleaning belt

Standard rubber fails above ~80°C; EPDM, silicone, aramid or glass-fibre belts required for hot duty

Bearings

High-temperature grease, extended housings, optional PT100 probes

Typical applications

Clinker and cement raw mix, sinter and coke handling, calcined lime, foundry returned sand, dried biomass, hot slag and DRI lines

Key benefit

Protects crusher wear parts and liners and downstream mills from destructive steel tramp iron even when the material is too hot for a standard unit

What Counts as "Hot Material" in Magnetic Separation?

Direct answer: In iron removal practice, "hot material" means a conveyed burden whose surface temperature at the magnet position exceeds roughly 80°C — the continuous operating ceiling of standard neodymium circuits and of ordinary rubber cleaning belts.

A surprising number of mining and minerals flows sit above that line for at least part of the time:

  • Cement clinker leaving a grate cooler commonly runs at 100–150°C at the discharge conveyor.
  • Sinter, coke and pellet feed on hot-screen or hot-transfer conveyors range from 100°C to well over 200°C.
  • Calcined lime and kiln feeds leave coolers between 100°C and 200°C.
  • Foundry returned sand after shakeout runs at 60–150°C.
  • Dried biomass, wood chips and grain from drum or belt dryers sit at 60–90°C.
  • Furnace slag, sponge iron and hot DRI fines range from about 80°C to several hundred degrees.

The number that matters is not the nameplate process temperature. It is the surface temperature of the burden directly beneath the magnet face, measured across a full shift including start-up spikes, because heat reaches the separator by radiation and by conduction through the iron it captures — not just through the air. For context on how magnetic iron removal fits into the wider plant flow, see the site's overview of magnetic separation equipment and the full range of industrial magnetic separators.Can a Self-Cleaning Magnetic Separator Remove Iron From Hot Material Above 80°C? 1

Why Does 80°C Matter So Much to a Standard Self-Cleaning Magnet?

Direct answer: Because 80°C is the continuous operating limit of the standard (N-grade) neodymium magnet material used in most self-cleaning separators. Above it, field strength decays — first reversibly, then permanently.

The two decay mechanisms

All permanent magnets have a negative temperature coefficient. For neodymium, each 1°C rise reduces magnetic output by roughly 0.11–0.13%. Two consequences follow:

  • Reversible decay. At 80°C, a magnet delivers about 7–8% less force than at 20°C. The force comes back when the magnet cools — but while it is hot, the deepest and finest tramp iron slips through, with no visible warning.
  • Irreversible loss. Above the grade's rated limit, the internal magnetic domains are disturbed and do not fully re-align on cooling. The field that is lost never comes back. If the material reaches the Curie point of neodymium, around 310–340°C, the "magnet" becomes an ordinary steel box.

A single afternoon of overheating can therefore write off a magnet circuit — even though the unit looks perfectly normal the next morning.Can a Self-Cleaning Magnetic Separator Remove Iron From Hot Material Above 80°C? 2

Conclusion

Direct answer: A self-cleaning magnetic separator removes iron from material above 80°C when — and only when — its magnetic circuit, belt, bearings and shielding are chosen for the actual measured temperature, not the catalogue default.

Three habits separate plants that get years of protection from plants that quietly feed steel into their crushers. First, measure the burden temperature at the magnet position and treat the peak, not the average, as the design point. Second, remember that the magnet is only one link in a thermal chain: belts, grease, chains and scrapers usually fail first and cheaply if specified correctly. Third, keep a gauss map and a temperature log so decay shows up on a dashboard before it shows up as a broken jaw plate. For a duty above 150°C, ferrite or cooled electromagnetic circuits are the proven routes; between 80°C and 200°C, high-coercivity NdFeB with a heat shield gives the best balance of capture depth and cost. If you share your belt width, tonnage and measured temperature profile, a competent supplier will size the circuit and hand you the derated performance curve — ask for it before you buy.

Related Articles

Related Products

  • Self-Cleaning Overband Magnet for Hot Conveyors
  • Electromagnetic Overband Separator
  • Iron Magnet
  • Magnetic Drum Separator
  • Magnetic Roller and Head Pulley
  • Drum and Roller Magnetic Systems

Related Technical Guides

  • Improve Fine Screening Efficiency with Polyurethane Screen Panels
  • Flotation Cell Rotor and Stator Wear Parts Guide
  • Rotor and Stator in Mechanical Flotation Cells
  • Hydrocyclone Wear: Root Causes and Material Solutions
  • Self-Cleaning Screen vs Woven Wire Mesh

Related Buyer Guides

  • How Do I Choose the Right Rubber Belt for a Vacuum Belt Filter?
  • Which Manufacturer Offers High-Quality Polyurethane Tufflex Wire Screens for Mining?

Related Comparison Articles

  • Polyurethane Screen vs Rubber Screen vs Wire Mesh Comparison
  • Self-Cleaning Screen vs Traditional Woven Wire Mesh Comparison

Contact Us

Contact: Annie Lu

Email: annie.lu@huataogroup.com

Phone / WhatsApp: +86 180 3242 2676

Website: http://www.tufflexscreen.com

We warmly welcome customers from around the world to contact us and establish mutually beneficial partnerships.

prev
Self-Cleaning Overband Magnet vs Metal Detector + Diverter
recommended for you
Get in touch with us
Customer service