Huatao Group-Vibrating Screen Technology Solution and Service for Quarry & Mining Industry Since 2008.
For in-line mounting, tilt the magnet 5–15° above the head pulley so the pole face follows the material trajectory; for cross-belt mounting keep the magnet at 90° to the belt, with no more than 30° of skew. Then set the discharge chute at 50–60° from horizontal. The chute angle, not the magnet angle, is what actually stops iron from sliding back.
Customer type: 800 t/h iron ore crushing and screening plant, two-stage crushing, 1,200 mm main conveyor.
Ore type: Magnetite-haematite blend, bulk density 2.1 t/m³, moisture 4–6%, lump size up to 250 mm.
Operating conditions: Cross-belt overband magnet mounted in a transfer tower with 1.4 m of head room, skewed 26° to clear a walkway, suspension gap 380 mm, discharge chute at 38° into a side bin. Belt speed 2.8 m/s.
Problem: The unit captured iron well but discharged poorly. Operators were clearing 10–18 pieces per shift from the gap between magnet and belt, and the chute lip built a ridge of iron and fines within four hours. Two crusher liner sets were consumed in 11 months, and the plant suspected the magnet was "not strong enough" and had budgeted for a larger electromagnetic replacement.
Solution: The magnet was not replaced. The unit was re-mounted in-line above the head pulley at a 12° tilt with the pole face set on the material trajectory, gap reduced to 260 mm, and the discharge chute rebuilt at 55° with a 20 mm polyurethane liner and 140 mm clearance to the return strand. Structure within 500 mm of the pole face was changed from mild steel to stainless. Commissioning used 12 pieces of real tramp iron (4–9 kg) at design tonnage.
Result: Test-piece capture rose from 71% to 96% at the new gap. Iron returning to the belt fell by roughly 80% within the first week, and chute-lip cleaning dropped from twice per shift to once per week. Crusher liner life extended by about 25% over the following 12 months, and the planned USD 90,000 separator replacement was cancelled. The only recurring cost added was the chute liner, replaced once in 14 months.
The lesson is blunt: the angle was wrong, not the magnet.
What slope should a self-cleaning overband magnet be mounted at?
Use 5–15° of tilt for in-line mounting above a head pulley, with 20° as a practical maximum, and mount cross-belt units at 90° to the belt. Then set the discharge chute at 50–60° from horizontal. If you can only remember one number, remember the chute angle — it is what stops iron sliding back into the stream.
Why does my magnet pick iron up and then drop it back on the belt?
Almost always because the discharge chute back plate sits inside the natural throw of the cleat belt, or because the chute is shallower than 45°. The iron hits steel, loses energy and falls through the gap. Move the chute 100–150 mm further out, raise the slope to 50–60°, and check that the cleat belt is running at its rated speed.
Contact: Annie Lu
Email: annie.lu@huataogroup.com
Phone / WhatsApp: +86 180 3242 2676
Website: http://www.tufflexscreen.com
We warmly welcome customers from around the world to contact us and establish mutually beneficial partnerships.
Contact: Annie Lu
Tel: +86 18032422676
E-mail: manager11@huataogroup.com
Address: Zhonghua North Street, Shijiazhuang, Hebei, China